Digital Diagnostic Functions
SOPTIC’s SFP+10GB-DB20-D is hot pluggable 3.3V Small Form-Factor transceiver module .It designed expressly for high-speed communication applications that require rates up to 10.7Gb/s ,it designed to be compliant with SFF-8472 SFP+MSA . The module data link up to 20km in 9/125um single mode fiber .The optical output can be disabled by a LVTTL logic high-level input of Tx Disable .Tx Fault is provided to indicate that degradation of the laser . Loss of signal(LOS) Output is provided to indicate the loss of an input optical signal of receiver or the link status with partner .
Product Features
Up to 10.7Gbps Data Links
Single Mode LC Receptacle Bi-directional transceiver
Up to 20km transmission on SMF
Power dissipation<1.0W
1330nm DFB laser and 1270nm PIN receiver
2-wire interface with integrated Digital Diagnostic monitoring
EEPROM with Serial ID Functionality
Compliant with FC_PI_4REV 7.0
Compliant with SFP+MSA with duplex LC connector
Single +3.3V Power Supply and LVTTL Logic
Operating Case temperature : -40~+70
Applications
10GBSE-BX at 10.3125Gb/s
10GBASE-BX at 9.953
8XFC at 8.5Gbps
4XFC at 4.25Gpbs
2XFC at 2.125Gpbs
1XFC at 1.0625Gpbs
1. Absolute Maximum Ratings
Rating |
Symbol |
Min |
Max |
Units |
Ref. |
Storage Temperature |
Ts |
-40 |
+85 |
℃ |
|
Storage Ambient Humidity |
HA |
5 |
95 |
% |
|
Operating Relative Humidity |
RH |
- |
85 |
% |
|
Power Supply Voltage |
Vcc |
-0.3 |
4 |
V |
|
Signal Input Voltage |
Vcc-0.3 |
Vcc+0.3 |
V |
2. Recommended Operating Conditions
Parameter |
Symbol |
Min |
Typ |
Max |
Units |
Ref. |
Ambient operating Temperature |
TA |
0 |
- |
70 |
℃ |
Without air flow |
Power supply Voltage |
VCC |
3.14 |
3.3 |
3.47 |
V |
|
Power supply current |
ICC |
- |
- |
300 |
MA |
|
Data rate |
BR |
10.3125 |
Gbps |
|||
Transmission Distance |
TD |
- |
20 |
KM |
Note(1) |
|
Coupled Fiber |
Single Mode fiber |
ITU-T G6.652 |
1. Specification of Transmitter
Parameter |
Symbol |
Min |
Typ |
Max |
Units |
Ref. |
Average Launched power |
PO |
-6 |
- |
-1 |
DBM |
|
Average Launched power(laser off) |
POUT-OFF |
- |
- |
-30 |
DBM |
Note(1) |
Optical Modulation Amplitude |
OMA |
-3 |
- |
- |
DBM |
Note(1) |
Center wavelength range |
λC |
1320 |
1330 |
1340 |
NM |
|
Side mode suppression ratio |
SMSR |
30 |
- |
- |
DB |
|
Spectrum bandwidth(-20db) |
б |
- |
- |
1 |
Nm |
|
Extinction ratio |
ER |
3.5 |
6 |
- |
DB |
Note(2) |
Output eye Mask |
Compliant with FC_PI-4REV 7.0 |
Note(2) |
2. Note(1) : The optical power is launched into SMF
Note(2) : Measured with RPBS2^31_1 Test pattern @ 10.3125Gbs
4. Specification Of Receiver
Parameter |
Symbol |
Min |
Typ |
Max |
Units |
Ref. |
Input optical wavelength |
Λin |
1260 |
1270 |
1280 |
nm |
|
Receiver Sensitivity in average |
PIN |
- |
- |
-15 |
DBM |
Note(1) |
Input saturation power (overload) |
PA |
-0.5 |
- |
- |
DBM |
Note(1) |
LOS-Assert power |
PA |
-30 |
- |
- |
DBM |
|
LOS-Deassert power |
PD |
- |
- |
-15 |
DBM |
|
LOS-Hysteresis |
PHys |
0.5 |
- |
4 |
DB |
Note (1) : Measured with RPBS2^31_1 TEST Pattern @ 10.3125Gbs BER=<10^-12
1.Electrical interface Characteristics
Parameter |
Symbol |
Min |
Typ |
Max |
Units |
Ref. |
Total power supply current |
ICC |
- |
- |
300 |
mA |
|
Transmitter |
||||||
Differential data input vlotage |
VDT |
180 |
- |
700 |
mVp-p |
|
Differential line input impedance |
RIN |
85 |
100 |
115 |
Ohm |
|
Transmitter fault output-high |
VFaultH |
2.4 |
- |
Vcc |
V |
|
Transmitter fault output-Low |
VfaultL |
-0.3 |
- |
0.8 |
V |
|
Transmitter disable voltage-high |
VDisH |
2 |
- |
Vcc+0.3 |
V |
|
Transmitter disable voltage=Low |
VDisL |
-0.3 |
- |
0.8 |
V |
|
Receiver | ||||||
Differential data output voltage |
VDR |
300 |
- |
850 |
mVp-p |
2 |
Differential Line output voltage |
ROUT |
80 |
100 |
120 |
Ohm |
|
Receiver LOS Pull up resistor |
RLOS |
4.7 |
- |
10 |
KOhm |
|
Data output Rise/Fall time |
Tr/fr |
20 |
- |
- |
Ps |
|
LOS output Voltage-High |
VLOSH |
2 |
- |
Vcc |
V |
|
LOS output Voltage-Low |
VLOSL |
-0.3 |
- |
0.4 |
V |
1.Pin Description
Pin Num. |
Name |
Function |
Notes |
1 |
VeeT |
Transmitter Ground |
|
2 |
TX Fault |
Module Transmitter Fault |
Note 1 |
3 |
TX disable |
Transmitter disable;Turns off transmitter laser output |
Note 2 module disables on high or open |
4 |
SDA |
2-wire serial interface date line(same as MOD-DEF2 as defined in the INF-8074i) |
Note 3,2 write serial ID interface |
5 |
SLC |
2-wire serial interface Clock(same as MOD-DEF1 as defined in the INF-8074i) |
Note 3,2 write serial ID interface |
6 |
MOD-ABS |
Module absent,connected to VeeT or VeeR in the module |
Note 3,Grounded in module |
7 |
RS0 |
Not used |
Function not available |
8 |
RX_LOS |
Receiver loss of signal indication(in FC designated as RX_LOS,in SONET designated as LOS,and in ethernet designated at signal detect) |
Note 4 |
9 |
RSI |
Not used |
Function not available |
10 |
VeeR |
Module receiver Ground |
Note 5 |
11 |
VeeR |
Module receiver Ground |
Note 5 |
12 |
RD- |
Receiver inverted data output |
Note 6 |
13 |
RD+ |
Receiver non-inverted data output |
Note 7 |
14 |
VeeR |
Module receiver Ground |
Note 5 |
15 |
VccR |
Module receiver 3.3V suply |
3.3± 5% Note 7 |
16 |
VccT |
Module transceiver 3.3V supply |
3.3± 5% Note 7 |
17 |
VeeT |
Module transceiver Grond |
Note 5 |
18 |
TD+ |
Transmitter Not-inverted data input |
Note 8 |
19 |
TD- |
Transmitter inverted data input |
Note 8 |
20 |
VeeT |
Module transmitter Ground |
Note 5 |
SOPTIC of SFP Optical Transceivers can be used and interchanged on a wide variety of Cisco or MSA compliant SFP products. They can be intermixed in combinations of 1000BASE-SX, 1000BASE-LX/LH, 1000BASE-EX, 1000BASE-ZX, or 1000BASE-BX10-D/U on a port-by-port basis.
SOPTIC of SFP Optical Transceivers are designed for use with SOPTIC SFP Media Converter, Industrial Ethernet Switches, IOLAN SCG Console Servers and third party equipment that supports SFP transceivers. Select the appropriate tab above to view Duplex, Simplex( BiDi ), CWDM or 10 Gigabit SFP+ and XFP Models.
SFP Optical module, another name is SFP transceiver. The function of the optical module is photoelectric conversion. The sending end converts the electrical signal into the optical signal. After the transmission through the optical fiber, the receiving end converts the optical signal into the electrical signal. SFP is a kind of light module.
Why Choose Us
Leader Supplier Of Optical Transceiver Modules.
RoHS Compliance
Active Environmental Policy
100% Guarantee Quality
Manufactured Under Strict Controls
100% Tested
Competitive Price And Service
Delivery Time:1-2 Day After Orders
Free Samples Are Available
Provide New Design For Customer Requirements
90% Off Shipping Cost By DHL UPS DEDEX Or TNT
Corporate Policy
http://www.sopticom.com/